Log File Format

If Session Data Logging has been enabled, after each programming or testing session a record is written to the log file (a line-oriented ASCII file). An example of a TaskLink log file is shown below.

Note: Information shown in brown is included in the Session Log if custom logging is enabled. In an actual Session Log, the text is not brown.

Note: Information shown in blue is included in the Session Log if the optional Version Control feature is enabled. In an actual Session Log, the text is not blue.

Note: Yield is the running percentage of devices that were programmed with no errors.

--------------------------------------------------------------------------------

   TL Session Sample Data Log - Version 7.0.0.0

 

Date Logged:

02-01-2010 03:55:29 PM

Task Name:

A-TASK_VERIFY

Archived Job Name:

A-TASK_VERIFY_J

User ID:

Administrator Mode

System:

PP/PS Series FlashCORE

Machine ID:

8688:PS588_1

 

 

Run Code:

1234

Operator ID:

5678

Handler ID:

PS-05

 

 

Device:

INTEL TE28F800C3BA TSOP48

Data Source:

E:\DATAFILE\1MB_PAT.BIN

Sumcheck:

44F4C68B

Process:

Continuity/ID Check/Verify/Vision

Process Status:

Job Begin Status: New Job, Job End Status: Completed

TLWin Session ID:

< none >

 

 

Job Start Time:

02-01-2010 03:53:06 PM

Job End Time:

02-01-2010 03:55:29 PM

Devices Total:

22

Devices Passed:

22

Devices Failed:

0

Overall Device Yield:

100.00%

 

 

Archived Job Directory:

D:\TLWin\Software\MyArchivedJobs\A-TASK_VERIFY_J

Archived Job State:

Ready

Archived Job Desc:

A-TASK_VERIFY archived job description

 

 

Nominal Throughput:

1512 dph

Job Throughput:

1277 dph

Devices Picked Input:

22

Devices Failed Vision:

0

Devices Failed REST:

0

Devices Missing/In Use:

0

 

 

Job Elapsed Time:

0 Hours 2 Minutes 23 Seconds

Job Setup Time:

0 Hours 1 Minutes 2 Seconds

Job Processing Time:

0 Hours 0 Minutes 57 Seconds

Job Assistance Time:

0 Hours 0 Minutes 5 Seconds

Job Shutdown Time:

0 Hours 0 Minutes 19 Seconds

 

 

Algorithm:

2736910C.ELF

Algorithm Status:

Released

Algorithm Author:

Data I/O

Alg COM Dll:

< not used >

Alg COM Dll Version:

< not used >

 

 

TaskLink Version:

7.50

AH500 Version:

5.3.120

Firmware Version:

05.41.00.C

Serialization Program:

< not used >

Serialization Prog Ver:

< not used >

 

 

Input Media:

Trays

Output Media:

Trays

Reject 1:

Reject Tray

Reject 2:

n/a

 

 

Starting Serial Number:

N.A.

Ending Serial Number:

N.A.

Serial Pass Report:

N.A.

Serial Fail Report:

N.A.

 

 

Programmer Board Configuration for: Site 1

Bkpln Brd Id:

2

Cntrl Brd Id:

2

Wvfrm Brd Id:

17

Adptr Brd Id:

3

 

Category

PASS

CF

NB

IB

PF

VF1

VF2

FT1*

FT2*

SFF*

SFB*

DO

EF

EID

OE

TotalStats

22

3

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 1 Skt 1

8

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 1 Skt 2

0

3

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 1 Skt 3

7

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 1 Skt 4

7

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 3 Skt 1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 3 Skt 2

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 3 Skt 3

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 3 Skt 4

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 4 Skt 1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 4 Skt 2

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 4 Skt 3

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 4 Skt 4

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 5 Skt 1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 5 Skt 2

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 5 Skt 3

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 5 Skt 4

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 6 Skt 1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 6 Skt 2

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 6 Skt 3

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 6 Skt 4

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 7 Skt 1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 7 Skt 2

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 7 Skt 3

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 7 Skt 4

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 8 Skt 1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 8 Skt 2

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 8 Skt 3

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 8 Skt 4

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 9 Skt 1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 9 Skt 2

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 9 Skt 3

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 9 Skt 4

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 10 Skt 1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 10 Skt 2

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 10 Skt 3

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 10 Skt 4

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 11 Skt 1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 11 Skt 2

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 11 Skt 3

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 11 Skt 4

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 12 Skt 1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 12 Skt 2

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 12 Skt 3

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Site 12 Skt 4

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

--------------------------------------------------------------------------------

 

The ‘TotalStats’ line and 'Site 1 Skt 1' through 'Site 2 Skt 4' lines contain comma-delimited information structured in the following format:

Field

Description

PASS

Devices that successfully programmed

CF

Devices that failed the continuity test

NB

Devices that were non-blank prior to programming

IB

Devices that contained an illegal bit

PF

Devices that failed the programming operation

VF1

Devices that failed during the first verify pass

VF2

Devices that failed during the second verify pass

DO

Devices with an overcurrent error

EF

Electrically erasable devices that failed to erase

EID

Devices with an electronic ID that did not match the selected device type

OE

Devices that failed due to errors other than those listed above

 

 

• • •